from the DARPA Atlantic SATNET Program (1979) P is for patching. |
1. Manual Pages
2. Table of Contents
3. SYNOPSIS
ntplogtemp [-h] [-l LOGFILE] [-o] [-w WAIT] [-v] [-V]
-h, --help show this help message and exit -l LOGFILE, --logfile LOGFILE append log data to LOGFILE instead of stdout -q, --quiet be quiet -o, --once log one line, then exit -w WAIT, --wait WAIT wait WAIT seconds after each log line, default 60 -v, --verbose be verbose -V, --version show program's version number and exit
4. DESCRIPTION
ntplogtemp gathers temperature readings across a system. The standard user is ntpuser and should have permissions to execute lm_sensors and smartctl.
The default is to write the data to stdout once every 60 seconds. The log file looks like:
# time, sensor, value 1485816568 ZONE0 39.0 1485816568 ZONE1 20.0 1485816568 ZONE2 42.0 1485816568 ZONE3 0.0
Time
is the POSIX time of when the log line is written.
Sensor
is the sensor the temperature reading was obtained from.
Value
is the temperature reading in celsius.
5. OPTIONS
-h, --help
-
Displays usage information and exits.
-l LOGFILE, --logfile LOGFILE
-
Append log data to LOGFILE instead of stdout
-q, --quiet
-
Quiet output, will not display errors
-o, --once
-
Log the data once, then exit
-v, --verbose
-
Be verbose
-w WAIT, --wait WAIT
-
Wait WAIT seconds after each log line. The default is 60 seconds. The minimum wait time is 5 seconds.
-V, --version
-
show program’s version number and exit
6. USAGE
ntplogtemp
-
This the simplest use of this program. It can be used to check the temperature readings of Zones, CPU, and disk drives every minute.
ntplogtemp -l /var/log/ntpstats/temperature -w 60 &
-
This will continuously log the temperature data in the background to the file /var/log/ntpstats/temperature. Only log every 60 seconds.
7. EXIT STATUS
One of the following exit values will be returned:
- 0 (EXIT_SUCCESS)
-
Successful program execution.
- 1 (EXIT_FAILURE)
-