Introduction

Device Firmware Update is a standard that allows USB devices to be easily and safely updated by any operating system.

Firmware Format

The daemon will decompress the cabinet archive and extract a firmware blob in DFU or DfuSe file format.

This plugin supports the following protocol IDs:

  • org.usb.dfu
  • com.st.dfuse

GUID Generation

These devices use the standard USB DeviceInstanceId values, e.g.

  • USB\VID_273F&PID_1003&REV_0001
  • USB\VID_273F&PID_1003
  • USB\VID_273F

Update Behavior

A DFU device usually presents in runtime mode (with optional DFU runtime), but on detach re-enumerates with an additional required DFU descriptor. On attach the device again re-enumerates back to the runtime mode.

For this reason the REPLUG_MATCH_GUID internal device flag is used so that the bootloader and runtime modes are treated as the same device.

Implementation Notes

The runtime mode is just as important as the DFU mode from the point of view of fwupd and should be included if firmware updates are to “just work”. Without a DFU runtime interface we can match the device with Flags = no-dfu-runtime but will need a suitably new fwupd version before the device is recognized.

The USB interface revision (REV) is used as the BCD version number, as DFU has no way of representing a firmware version number. A new firmware version should always increment the USB REV of the runtime interface as fwupd will not switch the device into DFU mode during enumeration to read the version number. The version number of the DFU mode should represent the bootloader version and this should not change as the firmware is updated.

The runtime USB interface should have a unique vendor ID and product ID for the specific firmware stream. A different version of software should have a unique VID/PID USB descriptor pair. The microcontroller example VID/PID should never be used in the runtime mode otherwise fwupd would not know what firmware to match.

Ideally, the bootloader should also have a unique USB vendor ID and product ID. This allows fwupd to more easily recognize the runtime interface going away and the DFU interface coming back. If the VID/PID is the same in runtime and DFU modes then the quirk Flags = no-pid-change is required.

If the bootloader VID/PID is not customized (as might be the default for the supplied MCU) then fwupd can match the runtime VID/PID to the bootloader VID/PID. Where this fails is when the device is stuck in the DFU mode, perhaps because the user removed the USB cable before the device had completed updating. With a unique VID/PID fwupd can recover the device stuck in DFU mode, reflashing the device with the latest matching firmware and then attaching it back into runtime mode.

Using a generic VID/PID for the bootloader means fwupd does not know how to recover the device back into runtime mode as the client does not know what firmware to choose and the user is forced to either RMA the device, or to download the correct file manually from the vendor vebsite and use low-level commands like sudo fwupdtool install-blob.

Vendor ID Security

The vendor ID is set from the USB vendor, for example USB:0x0A12

Quirk Use

This plugin uses the following plugin-specific quirks:

DfuFlags

Optional quirks for a DFU device which doesn’t follow the DFU 1.0 or 1.1 specification.

Since: 1.0.1

DfuForceVersion

Forces a specific DFU version for the hardware device. This is required if the device does not set, or sets incorrectly, items in the DFU functional descriptor. If set to 0000 then the DFU functionality is disabled.

Since: 1.0.1

DfuForceTimeout

Forces a specific device timeout, in ms.

Since: 1.4.0

DfuForceTransferSize

Forces a target transfer size, in bytes.

Since: 1.5.6

External Interface Access