# -*- coding: utf-8 -*- #=============================================================================== # User variable settings to specify a coupling computation environnement. # A coupling case is defined by a dictionnary, containing the following: # Solver type ('Code_Saturne', 'SYRTHES', 'NEPTUNE_CFD' or 'Code_Aster') # Domain directory name # Run parameter setting file # Number of processors (or None for automatic setting) # Optional command line parameters. If not useful = None #=============================================================================== # Ensure the correct SYRTHES install is used. sys.path.insert(1, '') # Define coupled domains domains = [ {'solver': 'Code_Saturne', 'domain': 'fluid', 'script': 'runcase', 'n_procs_weight': None, 'n_procs_min': 1, 'n_procs_max': None} , {'solver': 'SYRTHES', 'domain': 'solid', 'script': 'solid-coupling.syd', 'n_procs_weight': None, 'n_procs_min': 1, 'n_procs_max': None, 'opt' : '-v ens'} # Additional SYRTHES options # (ex.: postprocessing with '-v ens' or '-v med') ]