IBM FlashSystem 840/900 driver

IBM FlashSystem 840/900 driver

The volume driver for FlashSystem provides OpenStack Block Storage hosts with access to IBM FlashSystems.

This driver is to be used with IBM FlashSystem 840/900 systems only. For any other FlashSystem storage systems (including 5xxx, 7xxx, and 9xxx platforms) see the IBM Spectrum Virtualize family volume driver documentation.

Supported operations

These operations are supported:

  • Create, delete, attach, and detach volumes.

  • Create, list, and delete volume snapshots.

  • Create a volume from a snapshot.

  • Copy an image to a volume.

  • Copy a volume to an image.

  • Clone a volume.

  • Extend a volume.

  • Get volume statistics.

  • Manage and unmanage a volume.

Configure FlashSystem

Configure storage array

The volume driver requires a pre-defined array. You must create an array on the FlashSystem before using the volume driver. An existing array can also be used and existing data will not be deleted.

Note

FlashSystem can only create one array, so no configuration option is needed for the IBM FlashSystem driver to assign it.

Configure user authentication for the driver

The driver requires access to the FlashSystem management interface using SSH. It should be provided with the FlashSystem management IP using the san_ip flag, and the management port should be provided by the san_ssh_port flag. By default, the port value is configured to be port 22 (SSH).

Note

Make sure the compute node running the cinder-volume driver has SSH network access to the storage system.

Using password authentication, assign a password to the user on the FlashSystem. For more detail, see the driver configuration flags for the user and password here: Enable IBM FlashSystem FC driver or Enable IBM FlashSystem iSCSI driver.

There are some common configuration options for either driver:

List of common configuration options for IBM FlashSystem drivers

Flag name

Type

Default

Description

san_ip

Required

Management IP or host name

san_ssh_port

Optional

22

Management port

san_login

Required

Management login user name

san_password

Required

Management login password

IBM FlashSystem FC driver

Data Path configuration

Using Fiber Channel (FC), each FlashSystem node should have at least one WWPN port configured. If the flashsystem_multipath_enabled flag is set to True in the Block Storage service configuration file, the driver uses all available WWPNs to attach the volume to the instance. If the flag is not set, the driver uses the WWPN associated with the volume’s preferred node (if available). Otherwise, it uses the first available WWPN of the system. The driver obtains the WWPNs directly from the storage system. You do not need to provide these WWPNs to the driver.

Note

Using FC, ensure that the block storage hosts have FC connectivity to the FlashSystem.

Enable IBM FlashSystem FC driver

Set the volume driver to the FlashSystem driver by setting the volume_driver option in the cinder.conf configuration file, as follows:

volume_driver = cinder.volume.drivers.ibm.flashsystem_fc.FlashSystemFCDriver

To enable the IBM FlashSystem FC driver, configure the following options in the cinder.conf configuration file:

Description of IBM FlashSystem FC configuration options

Configuration option = Default value

Description

flashsystem_connection_protocol = FC

(String) Connection protocol should be FC. (Default is FC.)

flashsystem_multihostmap_enabled = True

(Boolean) Allows vdisk to multi host mapping. (Default is True)

IBM FlashSystem iSCSI driver

Network configuration

Using iSCSI, each FlashSystem node should have at least one iSCSI port configured. iSCSI IP addresses of IBM FlashSystem can be obtained by FlashSystem GUI or CLI. For more information, see the appropriate IBM Redbook for the FlashSystem.

Note

Using iSCSI, ensure that the compute nodes have iSCSI network access to the IBM FlashSystem.

Enable IBM FlashSystem iSCSI driver

Set the volume driver to the FlashSystem driver by setting the volume_driver option in the cinder.conf configuration file, as follows:

volume_driver = cinder.volume.drivers.ibm.flashsystem_iscsi.FlashSystemISCSIDriver

To enable IBM FlashSystem iSCSI driver, configure the following options in the cinder.conf configuration file:

Description of IBM FlashSystem iSCSI configuration options

Configuration option = Default value

Description

flashsystem_connection_protocol = FC

(String) Connection protocol should be FC. (Default is FC.)

flashsystem_iscsi_portid = 0

(Integer) Default iSCSI Port ID of FlashSystem. (Default port is 0.)

flashsystem_multihostmap_enabled = True

(Boolean) Allows vdisk to multi host mapping. (Default is True)

Note

On the cluster of the FlashSystem, the iscsi_ip_address column is the seventh column IP_address of the output of lsportip.

Note

On the cluster of the FlashSystem, port ID column is the first column id of the output of lsportip, not the sixth column port_id.

Limitations and known issues

IBM FlashSystem only works when:

open_access_enabled=off

Note

The flashsystem_multihost_enabled setting allows the driver to map a vdisk to more than one host at a time. This scenario occurs during migration of a virtual machine with an attached volume; the volume is simultaneously mapped to both the source and destination compute hosts. If your deployment does not require attaching vdisks to multiple hosts, setting this flag to False will provide added safety.

Creative Commons Attribution 3.0 License

Except where otherwise noted, this document is licensed under Creative Commons Attribution 3.0 License. See all OpenStack Legal Documents.