The PVMEFCDriver
and PVMEISCSIDriver
Cinder drivers allow the
Dell PowerVault ME Series storage arrays to be used for Block
Storage in OpenStack deployments.
To use the PowerVault ME Series drivers, the following are required:
PowerVault ME5 Series storage array with I200 or later firmware, or
PowerVault ME4 Series storage array with G280 or later firmware
iSCSI or Fibre Channel host interfaces
Network connectivity between the OpenStack hosts and the array’s embedded management interface
The HTTPS protocol must be enabled on the array
Create, delete, attach, and detach volumes.
Create, list, and delete volume snapshots.
Create a volume from a snapshot.
Copy an image to a volume.
Copy a volume to an image.
Clone a volume.
Extend a volume.
Migrate a volume with back-end assistance.
Retype a volume.
Manage and unmanage a volume.
Verify that the array can be managed via an HTTPS connection. HTTP
can also be used if driver_use_ssl
is set to False in the
cinder.conf
file.
Confirm that virtual pools A and B are already present on the array. If they are missing, create them.
Edit the cinder.conf
file to define a storage back-end entry for each
storage pool on the array that will be managed by OpenStack. Each entry
consists of a unique section name, surrounded by square brackets, followed
by options specified in a key=value
format.
The pvme_pool_name
value specifies the name of the storage pool
or vdisk on the array.
The volume_backend_name
option value can be a unique value, if you
wish to be able to assign volumes to a specific storage pool on the
array, or a name that is shared among multiple storage pools to let the
volume scheduler choose where new volumes are allocated.
The following cinder.conf
options generally have identical values
for each backend section on the array:
volume_driver
specifies the Cinder driver name.
san_ip
specifies the IP addresses or host names of the array’s
management controllers.
san_login
and san_password
specify the username and password
of an array user account with manage
privileges
driver_use_ssl
must be set to True to enable use of the HTTPS
protocol.
pvme_iscsi_ips
specifies the iSCSI IP addresses
for the array if using the iSCSI transport protocol
In the examples below, two back ends are defined, one for pool A and one for
pool B, and a common volume_backend_name
is used so that a single
volume type definition can be used to allocate volumes from both pools.
iSCSI example back-end entries
[pool-a]
pvme_pool_name = A
volume_backend_name = pvme-array
volume_driver = cinder.volume.drivers.dell_emc.powervault.iscsi.PVMEISCSIDriver
san_ip = 10.1.2.3,10.1.2.4
san_login = manage
san_password = !manage
pvme_iscsi_ips = 10.2.3.4,10.2.3.5
driver_use_ssl = true
[pool-b]
pvme_pool_name = B
volume_backend_name = pvme-array
volume_driver = cinder.volume.drivers.dell_emc.powervault.iscsi.PVMEISCSIDriver
san_ip = 10.1.2.3,10.1.2.4
san_login = manage
san_password = !manage
pvme_iscsi_ips = 10.2.3.4,10.2.3.5
driver_use_ssl = true
Fibre Channel example back-end entries
[pool-a]
pvme_pool_name = A
volume_backend_name = pvme-array
volume_driver = cinder.volume.drivers.dell_emc.powervault.fc.PVMEFCDriver
san_ip = 10.1.2.3,10.1.2.4
san_login = manage
san_password = !manage
driver_use_ssl = true
[pool-b]
pvme_pool_name = B
volume_backend_name = pvme-array
volume_driver = cinder.volume.drivers.dell_emc.powervault.fc.PVMEFCDriver
san_ip = 10.1.2.3,10.1.2.4
san_login = manage
san_password = !manage
driver_use_ssl = true
If HTTPS is enabled, you can enable certificate verification with the option
driver_ssl_cert_verify = True
. You may also use the
driver_ssl_cert_path
parameter to specify the path to a
CA_BUNDLE file containing CAs other than those in the default list.
Modify the [DEFAULT]
section of the cinder.conf
file to add an
enabled_backends
parameter specifying the backend entries you added,
and a default_volume_type
parameter specifying the name of a volume type
that you will create in the next step.
Example of [DEFAULT] section changes
[DEFAULT]
enabled_backends = pool-a,pool-b
default_volume_type = pvme
Create a new volume type for each distinct volume_backend_name
value
that you added in the cinder.conf
file. The example below assumes that
the same volume_backend_name=pvme-array
option was specified in all
of the entries, and specifies that the volume type pvme
can be used
to allocate volumes from any of them.
Example of creating a volume type
$ openstack volume type create pvme
$ openstack volume type set --property volume_backend_name=pvme-array pvme
After modifying the cinder.conf
file, restart the cinder-volume
service.
The following table contains the configuration options that are specific to the PowerVault ME Series drivers.
Configuration option = Default value |
Description |
---|---|
|
(List of String) List of comma-separated target iSCSI IP addresses. |
|
(String) Pool or Vdisk name to use for volume creation. |