Kernel driver pli1209bc¶
Supported chips:
Digital Supervisor PLI1209BC
Prefix: ‘pli1209bc’
Addresses scanned: 0x50 - 0x5F
Datasheet: https://www.vicorpower.com/documents/datasheets/ds-PLI1209BCxyzz-VICOR.pdf
- Authors:
 Marcello Sylvester Bauer <sylv@sylv.io>
Description¶
The Vicor PLI1209BC is an isolated digital power system supervisor that provides a communication interface between a host processor and one Bus Converter Module (BCM). The PLI communicates with a system controller via a PMBus compatible interface over an isolated UART interface. Through the PLI, the host processor can configure, set protection limits, and monitor the BCM.
Sysfs entries¶
in1_label  | 
“vin2”  | 
in1_input  | 
Input voltage.  | 
in1_rated_min  | 
Minimum rated input voltage.  | 
in1_rated_max  | 
Maximum rated input voltage.  | 
in1_max  | 
Maximum input voltage.  | 
in1_max_alarm  | 
Input voltage high alarm.  | 
in1_crit  | 
Critical input voltage.  | 
in1_crit_alarm  | 
Input voltage critical alarm.  | 
in2_label  | 
“vout2”  | 
in2_input  | 
Output voltage.  | 
in2_rated_min  | 
Minimum rated output voltage.  | 
in2_rated_max  | 
Maximum rated output voltage.  | 
in2_alarm  | 
Output voltage alarm  | 
curr1_label  | 
“iin2”  | 
curr1_input  | 
Input current.  | 
curr1_max  | 
Maximum input current.  | 
curr1_max_alarm  | 
Maximum input current high alarm.  | 
curr1_crit  | 
Critical input current.  | 
curr1_crit_alarm  | 
Input current critical alarm.  | 
curr2_label  | 
“iout2”  | 
curr2_input  | 
Output current.  | 
curr2_crit  | 
Critical output current.  | 
curr2_crit_alarm  | 
Output current critical alarm.  | 
curr2_max  | 
Maximum output current.  | 
curr2_max_alarm  | 
Output current high alarm.  | 
power1_label  | 
“pin2”  | 
power1_input  | 
Input power.  | 
power1_alarm  | 
Input power alarm.  | 
power2_label  | 
“pout2”  | 
power2_input  | 
Output power.  | 
power2_rated_max  | 
Maximum rated output power.  | 
temp1_input  | 
Die temperature.  | 
temp1_alarm  | 
Die temperature alarm.  | 
temp1_max  | 
Maximum die temperature.  | 
temp1_max_alarm  | 
Die temperature high alarm.  | 
temp1_crit  | 
Critical die temperature.  | 
temp1_crit_alarm  | 
Die temperature critical alarm.  |